Heating
Heating for your space
ClimateHub
Heating & cooling
What is a heat pump
Benefits of a heat pump
Sustainable future
Capacity:200L
Features
Mono type Tank integrated hydro unit
Heat Pump (A2W)
Power Supply (Indoor Unit) [Φ, #, V, Hz]
220~240V, 50Hz, 1Φ
Current Input (Nominal)
0.9 A
0.9 A
0.9 A
22.7 A
Capacity
14.00 kW
47,800 Btu/h
14.00 kW
16.00 kW
54,600 Btu/h
16.00 kW
Power
22.7 A
28.4 A
Power Input (Nominal)
0.2 kW
0.20 kW
0.2 kW
5.20 kW
Water Piping Connections (Mono)
Straight pipe
ø28 mm
ø28 mm
Space Heating Piping Connections
Straight pipe
ø28 mm
ø28 mm
DHW Piping Connections
Straight pipe
ø22 mm
ø22 mm
DHW Piping Connections (Secondary water)
N/A
N/A
Water Heating
L
A
DHW Tank
200 L
194 L
SUS 316L
10 bar
70 °C
3 (230V) kW
PU Foam
Backup Heater
2 (230V) kW
Safety Device
2.9 bar
○(5~60) LPM
7bar, 90℃
49~82±5(Auto, On : 15℃±3℃↓)90±5(Manual) °C
Expansion Vessel
8 L
0.3 Mpa
Water Pump (Primary)
BLDC Inv
9.5 mAq
Water Heat Exchanger
Braszed Plate Exchager
1.01(Water Side)0.98(Refrigerant Side) L
IP Class
IPX1
Sound
30 dBA
44 dBA
External Dimension (Indoor Unit)
130 kg
142 kg
595 x 1,800 x 700 mm
700 x 2,000 x 780 mm
Operating Temp. Range
10~46 ℃
-25~35 ℃
-25~43 °C
Leaving Water Temperature
15~65 °C
5~25 °C
Smart
N/A
N/A
N/A
N/A
App Connectivity
N/A
¹ The image shows an application example and is for illustrative purposes only. Please always check latest information for understanding availability of language versions. Available in 16 languages: English, German, French, Italian, Spanish, Polish, Portuguese, Dutch, Greek, Czech, Slovak, Finnish, Swedish, Norwegian, Danish, Lithuanian. ² Wi-Fi connection and Samsung SmartThings application account are required. Wi-Fi Kit to be ordered separately. Requires iOS 10.0 or later & Android 5.0 or later. ³ Based on internal testing of the 6 kW and 9 kW Split outdoor units (AE060RXEDEG, AE090RXEDEG, AE090RXEDGG). The noise level is measured 3m away from the front of the outdoor unit, in an anechoic room with an outside temperature of 7 °C. Results may vary depending on the model (capacity), environmental factors and individual use. Sound pressure levels are subject to execution and operating conditions.