am040fxmdeh eu 001 front white
am040fxmdeh eu 003 r perspective white
am040fxmdeh eu 004 dynamic white
rc125dhxeb 005 front open white
rc125dhxeb 006 r perspective open white

    Puissance:12.0KW

    Fiche:A+++

    Unité Extérieure Bibloc (R410A)

    AE120AXEDEHEU

    • Compatible SmartThings
    Trouver un installateur

    Efficiency

    The Samsung EHS includes a range of advanced functions that help optimize energy usage and are independently certified as delivering enhanced energy efficiency as compared to the previous models. The 2-Zone Control enables simultaneous heating with two different water temperature demands. The Photovoltaic Enabled feature checks the status of solar panels and adjusts the temperature to reduce network electricity usage. While the Smart Grid Ready feature helps users take advantage of economically efficient and sustainable power supply options.

    Eco-friendliness

    The Samsung EHS Mono and Split are designed to deliver both sophisticated heating capabilities and green living credentials demanded by modern households*. * https://www.samsung.com/semiconductor/about-us/green-management/

    Caractéristiques Produit

    • Caractéristiques

      Caractéristiques

      • Type

        EHS Split

      • Mode

        Pompe à chaleur Air/Eau

    • Power Supply (Indoor Unit) [Φ, #, V, Hz]

      Power Supply (Indoor Unit) [Φ, #, V, Hz]

      • 1Ф, 220~240V, 50Hz

    • Current Input

      Current Input

      • Froid (°C)

        14.00 A

      • Chaud (°C)

        11.70 A

    • Efficacité énergétique

      Efficacité énergétique

      • Eer (refroidissement) [w / w]

        3.87

      • Flic (chauffage) [w / w]

        4.63

      • Grade d'énergie du radiateur (55? C / 35? C)

        A+ / A+++

    • Puissance

      Puissance

      • Froid [kW]

        12.0 kW

      • Froid [Btu/h]

        40,900 Btu/h

      • Chaud [kW]

        12.0 kW

      • Chaud [Btu/h]

        40,900 Btu/h

    • Puissance

      Puissance

      • MCA

        28.0 A

      • MFA

        35.0 A

    • Power Input

      Power Input

      • Froid 1)

        3.10 kW

      • Chaud 2)

        2.59 kW

    • Compresseur

      Compresseur

      • Type

        BLDC Twin Rotary

      • Nom du modèle

        UG5TK5450FJX

      • Huile (Type)

        PVE

    • Ventilateur

      Ventilateur

      • Débit d'air (élevé / milieu / bas) [? / Min]

        99 CMM

    • Piping Connections

      Piping Connections

      • Installation Max. Hauteur [M]

        30 m

      • Tuyau liquide (?, Mm)

        9.52 mm

      • Tuyau liquide (?, Pouce)

        3/8"

      • Tuyau à gaz (?, Mm)

        15.88 mm

      • Tuyau à gaz (?, Pouce)

        5/8"

      • Installation Max. Longueur [m]

        50 m

    • Réfrigérant

      Réfrigérant

      • Type

        R410A(Contains fluorinated greenhouse gas, GWP=2,088)

      • Charge d'usine (kg)

        2.98 kg

      • Méthode de contrôle

        EEV

    • Caractéristiques Sonores

      Caractéristiques Sonores

      • Pression acoustique

        50 /51 dBA

      • Niveau de puissance

        64 / 64 dBA

    • Dimensions (unité intérieure)

      Dimensions (unité intérieure)

      • Poids net / kg)

        45.0 kg

      • Poids brut (kg)

        55.0 kg

      • Dimensions net (LxHxP) (mm)

        510 x 850 x 315 mm

      • Dimensions brut (LxHxP) (mm)

        564 x 1,024 x 412 mm

    • Plage de fonctionnement

      Plage de fonctionnement

      • Froid (°C)

        10~46 ℃

      • Chaud (°C)

        -25~35 ℃

      • Eau chaude domestique (° C)

        -25~43 °C

    • Température de départ d'eau

      Température de départ d'eau

      • Chaud (°C)

        15~55 °C

      • Froid (°C)

        5~25 °C

    • Poids et dimensions

      Poids et dimensions

      • Poids net / kg)

        100.5 kg

      • Poids brut (kg)

        110.0 kg

      • Dimensions net (LxHxP) (mm)

        940 x 1,420 x 330 mm

      • Dimensions brut (LxHxP) (mm)

        995 x 1,598 x 426 mm


    ¹ Based on testing by a third-party lab in accordance with ASTM B117, an official test method. For more details, please contact Samsung’s technical professionals. ² Based on testing by a third-party lab, applying the actual pressure of refrigerant for 1 minute, after a Salt Spray Test (SST) of over 2,280 hours. ³ Air-to-Water Condition : (Heating) Water In/Out 30 ℃/35 ℃, Outdoor Air 7 ℃[DB]/6 ℃[WB]; (Cooling) Water In/Out 23 ℃/18 ℃, Outdoor Air 35 ℃[DB]. ⁴ All Samsung EHS products comply to EU EcoDesign's Minimum Energy Performance Standards (MEPS). ⁵ Only available on certain models. Contact your local Samsung representative for complete product information. ⁶ Based on Samsung’s internal test results compared with the Samsung AR09FSSKABENEU model. Individual results may vary. ⁷ When testing Split 6 kW and 9 kW models based on internal testing in Samsung Korea. Results may vary depending on environmental factors and individual use. ⁸ Please refer to the installation manual for detailed anti-freeze specifications. Anti-Freeze Protection control should be used only for auxiliary measure in addition to glycol mixture.