Capacity:2.6KW
Features
features
2.6kW-1Φ-Console
Model Name
model_name
AC026RNJDKG/EU
AC026RXADKG/EU
System
system
Heat Pump
Capacity
capacity
0.98 / 2.60 / 3.40 kW
0.95 / 3.50 / 4.20 kW
Power Input
power_input
0.23 / 0.72 / 1.20 kW
0.21 / 1.06 / 1.45 kW
Current Input
current_input
1.6 / 3.6 / 5.5 A
1.3 / 5.0 / 7.0 A
Power
power
11.0 A
12.5 A
Energy Efficiency
energy_efficiency
SEER 6.4 (A++)
SCOP 4.2 (A+)
Piping Connections
piping_connections
6.35 mm
3/8"
9.52 mm
3/8"
20 m
15 m
Field Wiring
field_wiring
0.75mm2 ↑
Refrigerant
refrigerant
R32(Contains fluorinated greenhouse gases, GWP=675)
0.90 kg
0.61 tCO2e
EEV
Power Supply (Indoor Unit) [Φ, #, V, Hz]
power_supply_indoor_unit___v_hz
1, 2, 220~240, 50
Fan
fan
Turbo
(Cool) 7.5/6.8/6.0(Heat) 8.5/7.2/6.2 CMM
35 W
1 EA
Drain
drain
ID 18mm Hose mm
Sound
sound
36 / 31 / 26 / 23 dBA
53 dBA
External Dimension (Indoor Unit)
external_dimension_indoor_unit
16.0 kg
720 x 199 x 620 mm
Power Supply (Outdoor Unit) [Φ, #, V, Hz]
power_supply_outdoor_unit___v_hz
1, 2, 220~240, 50
Fan (Outdoor Unit)
fan_outdoor_unit
30 CMM
Sound (Outdoor Unit)
sound_outdoor_unit
46/47 dBA
59 dBA
External Dimension (Outdoor Unit)
external_dimension_outdoor_unit
32.5 kg
790 x 548 x 285 mm
Operating Temp. Range
operating_temp_range
-15~46 ℃
-20~24 ℃
Smart
smart
Yes
App Connectivity
app_connectivity
Yes
Subscribe to our newsletter to receive the latest product innovations, updates, and much more.