am040hcmdks eu 001 front beige 5c50d1af
am040hcmdks eu 002 r perspective beige 1990c90d
am040hcmdks eu 003 dynamic beige 7e33d9a4
am040hcmdks eu 004 front open beige 0de6a55f
am040hcmdks eu 005 r perspective open beige 09e87847
am040hcmdks eu 006 back beige 2bd69821

    Capacity:14.0kW

    DVM S Mini HR

    AM050HCMDKSEU

    Request a quote

    Comfort in every room

    The system can heat and cool different parts of a home at the same time, giving you more comfort and flexibility throughout the year.

    For example, bedrooms can be cooled with air-to-air units on a warm summer night, while floor heating or radiators keep the bathroom or living room cosy through the air-to-water system. It can also produce domestic hot water (DHW) while continuing to heat the home, so comfort never needs to pause.

    DVM S Mini HR Intro 2880x1440

    DVM S Mini R32 Heat Recovery features

    • Facade and windows of minimalist villa. Architecture by Tom Mahieu architect. Realized by Xavier Den Blauwen.

      Heating and cooling at the same time

      Unlike a standard heat pump that can only heat or cool at one time, the Heat Recovery system can do both simultaneously. For example, while one area of the building is being cooled, the heat removed from that space can be reused to heat another room or support domestic hot water (DHW) production instead of being wasted outdoors. This helps improve overall efficiency while keeping everyone comfortable.

      The system is also built to perform reliably in demanding conditions, with cooling operation from -5°C to 48°C and heating operation from -25°C to 26°C².

    • DVM S Mini HR Tab 2

      Designed with safety in mind

      The DVM S Mini R32 HR is designed to meet two of the key IEC 60335-2-40 safety requirements. In the Heat Recovery model, the shut-off valve is integrated into the HR changer, while the indoor unit includes a built-in R32 refrigerant leak detection sensor. In the event of a leak, the system can respond quickly for added peace of mind.

      Combined with Durafin™ Ultra³ technology, the unit is also protected against corrosion with a dual-layer coating that helps maintain long-term performance, even in challenging environments.

    • DVM S Mini HR Tab 3

      AI that works in the background

      Active AI features are included to make everyday comfort easier. AI Refrigerant Analysis continuously monitors system data and can alert users early if refrigerant levels are too low. At the same time, AI Pressure Control adapts to usage habits and changing conditions, helping maintain the right indoor comfort automatically — whether it’s a busy family home, a small office, or changing weather outside⁵.

    Designed to fit into spaces more easily

    The DVM S Mini R32 HR is designed with installers in mind. Its innovative 4-way directional piping system allows connections from multiple angles, making installation more flexible in tight or complex spaces. Whether it’s a residential project, renovation, or light commercial application, the design helps simplify installation and makes ongoing maintenance easier.

    DVM S Mini HR Combination 1

    Comfort, quietly delivered

    With Silent Mode⁵, sound-absorbing technology, and specially designed fans, the system helps reduce noise distractions during the day and night. For example, quieter nighttime operation with a reduced noise level of 3–7 dB(A)⁶ can help create a more restful environment while maintaining comfort in the background.

    DVM S Mini HR Combination 2 V2
    Hero Banner 2880x1390px

    SmartThings integration for connected climate control

    Integration with the SmartThings ecosystem app⁷, enables remote control, mode selection, and monitoring via a connected smart device even when users are not home.

    Discover more

    Documentation

    Declaration of Conformity

    Product Specifications

    • Features

      Features

      features

      • Type

        Outdoor DVM

    • Model Name

      Model Name

      model_name

      • Outdoor Unit

        AM050HCMDKS/EU

    • Power Supply

      Power Supply

      power_supply

      • Power Supply (Outdoor Unit) (Φ)

        1 Φ

      • Power Supply (Outdoor Unit) (#)

        2 #

      • Power Supply (Outdoor Unit) (V)

        220 - 240 V

      • Power Supply (Outdoor Unit) (Hz)

        50/60 Hz

    • System

      System

      system

      • Mode

        Heat Recovery

    • Performance (nominal)

      Performance (nominal)

      performance_nominal

      • 5 HP

    • Capacity (Rated)

      Capacity (Rated)

      capacity_rated

      • Cooling [kW]

        14.00 kW

      • Heating [kW]

        14.00 kW

      • Heating (Max)

        16.00 kW

    • Connectable Indoor Units

      Connectable Indoor Units

      connectable_indoor_units

      • Maximum Number of Connectable Indoor Units

        9 EA

      • Total Capacity of the Connected Indoor Units Min. (kW)

        7.00 kW

      • Total Capacity of the Connected Indoor Units Max. (kW)

        18.20 kW

    • Power Input

      Power Input

      power_input

      • Cooling [kW]

        4.83 kW

      • Heating [kW]

        3.37 kW

    • Current Input

      Current Input

      current_input

      • Cooling (℃)

        22.1 A

      • Heating (℃)

        15.4 A

    • Power

      Power

      power

      • MCA

        24 A

      • MFA

        32 A

      • Minimum Ssc

        - MVA

    • Energy Efficiency

      Energy Efficiency

      energy_efficiency

      • EER (Cooling) [W/W]

        2.90 W/W

      • COP (Heating) [W/W]

        4.15 W/W

      • SEER (Ducted)

        7.40 W/W

      • SCOP (Ducted)

        4.70 W/W

      • ŋs.c (Ducted)

        293.00 %

      • ŋs.h (Ducted)

        185.00 %

      • SEER (Non-Ducted)

        8.20 W/W

      • SCOP (Non-Ducted)

        5.10 W/W

      • ŋs.c (Non-Ducted)

        325.00 %

      • ŋs.h (Non-Ducted)

        201.00 %

      • Pdesignh

        8.50 kW

    • Casing

      Casing

      casing

      • Material (Body)

        GI Steel Plate

      • Material (Base)

        GI Steel Plate

    • Heat Exchanger (Outdoor Unit)

      Heat Exchanger (Outdoor Unit)

      heat_exchanger_outdoor_unit

      • Type

        Fin & Tube

      • Material (Fin)

        Albania

      • Material (Tube)

        Cu

      • Fin Treatment

        Anti-corrosion

    • Compressor

      Compressor

      compressor

      • Type

        Twin BLDC Rotary

      • Output (kW)

        4.256 kW

      • Model Name

        UB5TD8450FJX

      • Oil (Type)

        POE

      • Oil (Initial Charge) [cc]

        1500 cc

    • Fan

      Fan

      fan

      • Type

        Propeller

      • Discharge Direction

        Side

      • Quantity

        1 EA

      • Air Flow Rate [m3/min]

        77.00 ㎥/min

      • Air Flow Rate [l/s]

        1283 l/s

      • Motor (Output) [W]

        122 W

      • Number of Unit

        1 EA

    • Fan Motor

      Fan Motor

      fan_motor

      • Type

        BLDC

    • Piping Connections

      Piping Connections

      piping_connections

      • Liquid Pipe Type

        Braze Connection

      • Liquid Pipe Diameter (mm)

        9.52 mm

      • Liquid Pipe Diameter (inch)

        3/8 inch

      • Gas Pipe Type

        Braze Connection

      • Gas Pipe Diameter (mm)

        15.88 mm

      • Gas Pipe Diameter (inch)

        5/8 inch

      • Heat Insulation

        Both Liquid and Gas Pipes

      • Piping Length (ODU-IDU) Max. (Equiv.) (m)

        80 m

      • Piping Length (1st Branch-IDU) Max. (m)

        40 m

      • Total Piping Length (System) Max. (m)

        150 m

      • Level Difference (ODU in highest position) Max. (m)

        30 m

      • Level Difference (IDU in highest position) Max. (m)

        25 m

      • Level Difference (IDU-IDU) Max. (m)

        15 m

      • Discharge Gas Pipe Diameter (mm)

        15.88 mm

      • Discharge Gas Pipe Diameter (inch)

        5/8 inch

      • Discharge Gas Pipe Type

        Braze Connection

    • Refrigerant

      Refrigerant

      refrigerant

      • Type

        R32

      • Factory Charging (kg)

        2.20 kg

    • Sound

      Sound

      sound

      • Sound Pressure Level (Cooling)

        57 dB(A)

      • Sound Pressure Level (Heating)

        59 dB(A)

      • Sound Power Level (High)

        70 dB(A)

      • Sound Power Level (Low)

        74 dB(A)

    • External Dimension (Outdoor Unit)

      External Dimension (Outdoor Unit)

      external_dimension_outdoor_unit

      • Net Weight (kg)

        90 kg

      • Shipping Weight (kg)

        100 kg

      • Net Dimensions (Width) (mm)

        940 mm

      • Net Dimensions (Height) (mm)

        840 mm

      • Net Dimensions (Depth) (mm)

        460 mm

      • Shipping Dimensions (Width) (mm)

        1020 mm

      • Shipping Dimensions (Height) (mm)

        1030 mm

      • Shipping Dimensions (Depth) (mm)

        575 mm

    • Operating Temperature Range

      Operating Temperature Range

      operating_temperature_range

      • Cooling (Min) (°C)

        -5 ℃

      • Cooling (Max) (°C)

        48 ℃

      • Heating (Min) (°C)

        -25 ℃

      • Heating (Max) (°C)

        26 ℃

    • Field Wiring

      Field Wiring

      field_wiring

      • Transmission Cable

        0.75 ㎟

     

    Disclaimers

    1. GWP R32: 675 GWP R410A: 2088 R32 refrigerant charge

    2. If the indoor temperature is between 10°C and 15°C, the warming-up mode must be completed before it can work in heating mode to make it easier to understand and have a positive twist to it.

    3. 2kg tCO2e=1.49 R410A refrigerant charge 2.00 & 2.5 kg tCO2e=4.18 & 5.22 Reference: TDB

    4. Based on internal testing of the cooling operation, with the temperature set at 22°C and using Auto mode for 4 hours, at a room temperature of 33°C and an external temperature of 35°C. The tested model was an AM06EU0DXMDKG/EU connected to AM140DN4DKG/EU indoor unit with 25m of piping. The elapsed times were measured when the room temperature reached 25°C.

    5. Silent mode can be activated by the installer, depending on the model code, during the installation/service stage.

    6. Based on internal testing comparing silent mode with regular operating mode. The sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure levels may differ depending on operating conditions. Silent mode is available by option setting. Based on internal testing. Results may vary depending on environmental factors and individual use.

    7. A Wi-Fi connection and a Samsung SmartThings account are required. Requires iOS 10.0 or later and Android 5.0 or later.

    • Stay informed

      Subscribe to our newsletter to receive the latest product innovations, updates, and much more.

    • Contact us

      Reach out to our sales team to ask any questions you may have and discuss the best options for your business.